MASTER PLUS

ELECTRONICALLY CONTROLLED THERMAL AEROSOL DEVICES

General Considerations

The particles of disinfectant or disinfesting product generated by the Master Plus aerosol device having a diameter of less than a micron, give a uniform dispersion in the environment of the used medical product. As the micelles remain in suspension for a long time (about 2 hours), they determine a very effective action compared with traditional methods since a very small quantity of product disinfects or fumigates spaces of varying cubage in a very short time. It can be concluded that Master Plus is necessary in places where no moisture must be created in order to achieve environmental prophylaxis in a short time. Master Plus can be useful for disinfecting and / or disinfesting schools, domestic spaces, food premises, hospital wards, and wherever carrying out environmental disinfection is necessary.

Specifications:

  • Watts 2100 - 220 volt single phase - 50/60 herz 
  • 220 volt single phase motor 
  • Volumetric pump in graphite and viton 
  • Average consumption: 50 ml per minute 
  • Weight empty: 30 kg 
  • Electronic timer (range 2 to 240 minutes) 
  • Structure in satin stainless steel 
  • Control panel with digital timer and temperature programming 
  • Operating time table inserted in the side panel 
  • Methods of use in the control panel 
  • Warnings and maintenance in the side panel 
  • CE - EN 50082-1 standard
  • Warranty: 2 years

"End of liquid" safety device

The Master and Master Plus thermal aerosol apparatuses are provided with a supplementary safety device: 

  • A magnetic level sensor causes the immediate arrest of the equipment if there is no more liquid to nebulize. 
  • The LED, positioned centrally in the control panel (RESISTANCE) flashes to indicate the absence of liquid.

Instructions:

  1. Place the can of disinfesting product or disinfectant in the special compartment.
  2. Insert the plug into the connector already in place, then insert the plug into a 220 V single phase socket.
  3. Place the power switch in the ON position.
  4. Program the time of operation on the display in relation to the volume to be treated (see table times).
  5. Program the outlet temperature of the aerosol (maximum 60 °) on the display.
  6. Press the "cycle" button. Start the aerosol.
  7. You cannot change the time or temperature during operation.

Time Table and Average Consumption

Room to be treated
(m3)

Nebulization time
(minutes)
(minuti)

Consumtion
(milliliters)

500
1.000
1.500
2.000
2.500
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000

10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180

500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
9000


Warning

The MASTER thermal aerosol apparatuses can be electronically adjusted for a constant aerosol temperature according to the use of our insecticide or bactericide medical products. The constant temperature ensures correctly exploiting the principles used thus avoiding degradation of the product.

IMPORTANT

We disclaim any responsibility for improper use, disassembly and manipulation of electronics and mechanics.

 

TECHNICAL SHEET